![](https://fertkel.com/wp-content/uploads/2024/04/workstation.jpg)
IVF Workstation
![](https://fertkel.com/wp-content/uploads/2024/04/esco-Incubator.jpg)
Co2 Incubator (ESCO)
![](https://fertkel.com/wp-content/uploads/2024/04/MIRI-Multiroom-Incubator.jpg)
Bench Top Incubators ( MIRI - Multiroom Incubator)
![](https://fertkel.com/wp-content/uploads/2024/04/MINI-MIRI-HUMIDITY-MODEL-1.jpg)
Bench Top Incubators ( MINI MIRI HUMIDITY MODEL )
![](https://fertkel.com/wp-content/uploads/2024/04/MINI-MIRI-DRY-MODEL.jpg)
Bench Top Incubators ( MINI MIRI DRY MODEL )
![](https://fertkel.com/wp-content/uploads/2024/04/Time-lapse-Incubator.jpg)
Time lapse Incubator
![](https://fertkel.com/wp-content/uploads/2024/04/ICSI-Machine.jpg)
ICSI Machine
![](https://fertkel.com/wp-content/uploads/2024/04/Stereozoom-Microscopes.jpg)
Stereozoom Microscopes
![](https://fertkel.com/wp-content/uploads/2024/04/Testtube-Warmer.jpg)
Test Tube Warmer
![](https://fertkel.com/wp-content/uploads/2024/04/ICSI-Table.jpg)
ICSI Table
CelCulture® CO2 Incubator
FEATURES
• Fast temperature and gas recovery time using sophisticated firmware and optimally located precision sensors to monitor and control temperature, CO2 and O2 levels inside the chamber.
• Inner Door Kit helps the fast recovery of parameters reduces contamination risk, with each section having a dedicated door panel
Maximum protection against harmful contaminants
• 90°C moist heat decontamination cycle
• ULPA filter cleans the air so that chamber returns to ISO Class 5 cleanliness in 11 minutes upon door closing
• ISOCIDE™ antimicrobial coating
Different capacity models available
• Capacity models to suit different needs: 50 L model with 2 sections; 170 L model with 4 sections; 240 L model with 4 or 6 sections
Easy chamber calibration and validation
• Access ports provide easy calibration and validation of the chamber parameters
Certified embryo-safe
• 100% embryo survival on Mouse Embryo Assay (MEA) testing
MIRI- Multiroom Incubator
Specifications
No. of compartments
6 completely separate heating chambers
Heating method
Direct heat transfer via heated bottom, also with heated lid and heating optimization plate
Humidification
Dry incubation
Total capacity
Heating plates customized for several types of dishes,
e.g. Falcon® or Nunc®
24 x IVF 4-well dishes
24 x Petri dishes Ø 60 mm
48 x Petri dishes Ø 35 mm
Input gas
100% CO2, 100% N2 (premixed gas NOT required)
Fast recovery
– 1 minute temperature recovery
– 3 minutes gas recovery
HEPA/VOC filtered airstream
– YES
UV sterilized airstream
– YES, optional
Data logging
– YES, optional via supplied software.
Parameters of the machine that can be viewed:
• temperature of all monitored temperature and gas concentration points
• gas input pressures
• gas flow rates
• current gas readings
Alarms
– YES, audible+visible, for out-of-range parameters: temperature, gas concentration, and gas pressure (can be
connected to external monitoring systems)
Stackable
– YES
Certified!
– IEC/EN 60601-1 3rd edition
– EU MDD Class IIa Medical Device
Cleared!
– FDA 510(k)
MINI MIRI HUMIDITY MODEL
![mini](https://fertkel.com/wp-content/uploads/2024/04/mini.png)
The Mini MIRI® Humidity Incubator comes with a data logger software that monitors the temperature, gas concentration, gas input pressure, gas flow rates, and alarms. All real-time parameters can be viewed conveniently in graphs when the Mini MIRI® is connected to a PC and the data logger software can also monitor multiple incubators at the same time. Weekly reports can be exported for the users’ convenience.
MINI MIRI DRY MODEL
![mini miri dry](https://fertkel.com/wp-content/uploads/2024/04/mini-miri-dry.png)
The Mini MIRI® Dry Incubator is a dry IVF bench top incubator that can recirculate gas inside the incubator and is compatible with a VOC/HEPA filtration system unlike other humidified IVF incubators. Gas inserts (whether pure N2 and CO2 or premixed gas) first go through the tri-gas mixing chamber to achieve the set CO2 and O2 gas concentrations by the user and then into the VOC/HEPA filter before entering the incubator chambers. After this, gas now enters a UV Sterilization (254nm) table before going back to the tri-gas mixing chamber and recirculates the gas. This system ensures that there is minimal gas consumption even with lid openings of the incubator chambers while maintaining the recirculating air clean and safe for the embryo samples.